But you probably would not recover the cost of the battery within its lifetime. But your situation is complicated by already having a 3 kilowatt system. If that is the case it seems counter intuitive to me as I dont know if demand will outstrip production until I actually turn the appliance (eg A/C) on and check the display. Does anyone know how the limiter works in this scenario with 2 inverters? Shane, you appear to be mixing up kW and kWh easily done! Also note that for new installations in WA, only residences with inverters of 5 kilowatts or less can receive the states, Western Australias Western Power area: Perth and South West WA. 1. If youre not satisfied with what answers our calculator gives, let me know your figures for grid electricity and solar feed-in tariff and Ill come up with an estimate for you. Its the same with kW and hours of solar electricity production. When a home is exported limited, all the power the solar inverter can produce is available for the home to use. 0000028229 00000 n
), Finally understand, the article above is very well written for the layman So really apart from the requirement that the initial startup can only happy on voltages below 253v, I have no throttling until at least 285v and probably even higher. Seem most solar places, even the ones the go on about how good they are, arent that good when presented with this, what seems to be a conundrum for them. Energex doesnt automatically allow inverters over 5 kilowatts to be installed with export limiting, but currently regularly grants permission for single-phase homes on the main grid to install up to 10 kilowatts of inverter capacity with export limiting. Victorias AusNet network area: The eastern third of Victoria, not including Melbourne or French Island. So yeah, the Envoy is essentially all you need to configure export limiting or anything else if you have an Enphase microinverter set-up. Here at SolarQuotes, we had been hearing quite a few complaints about Powercors zero export limits. 0000010603 00000 n
Thanks Ron. The 7kW charger achieves full charge in 6 hours, and one 2. The loss figures above are for Sydney and are affected by the climate. Some say so you want to replace your system? Single-phase properties can have up to 5 kilowatts of inverter capacity, and 3 phase properties can have up to 30 kilowatts. About 50%. I am afraid Western Power is very strict. Victorias CitiPower area: The Melbourne Central Business District. Victoria's "Hotest" Solar Postcode is 3977 at last look. 3. Put down your weapons.3. DC Input Power (Wp) 10000, from its published datasheet. Technically, what will happen is the inverter will reduce the solar systems output so the generation will be forgone, but I dont want to go into too much detail in this article. No unfortunately. Has the oppressive authority in WA ever given a reason for not allowing export limited inverters in WA? IE if Im producing 8KW, the house is using 2KW it will still export 5kw? Under another option to . Youre using a total of four kilowatts to cook your lunch, so your home is exporting 4 kilowatts, which is below the limit. Now, that would help protect electricity grids, especially, the fragile, decrepit SWIS grid, for the present. Point Cook Solar limit export to zero by Powercor - Solar PV discussion Finally, there are profiles for other countries that run 220-240V networks, and its remarkable how many of them use the older AS4777.3:2005 standard in their countries, because for many of these countries, this is the only profile the Envoy offers. Contracts and resources for connection agreement, Vegetation clearing requirements for new powerlines, Registered Electrical Contractor resources, Rapid Earth Fault Current Limiters (REFCL), Endorsement for wholesale demand response. Allows installation but has a zero export limit. Would the gateway signal the micro inverters to shut down one at a time, or to all reduce output equally? And, no matter how powerful, the members of the legislatures imagine themselves to be, and, no matter how trump-like, they are, they can not stop the future. This is assuming that my understanding of what I have read, is correct; that such a system would be permitted, in a single phase connection to the SWIS grid. Fronius Wattpilot: A Smart EV Charger With A Short Warranty, You Wont Believe How Dumb The NSW Governments New Battery Calculator Is. 352 0 obj
<>stream
While export limiting is possible its not always approved. A man named Canute, proved that, centuries ago. 0000009027 00000 n
Just last week, Powercor (Western Victoria) advised that they now have more room in the grid for export. Am planning to install solar 6.6 kWh system and upon checking with powercor they are giving export limit as 0 kWh. Victorias Powercor area: Western Victoria, including a large portion of West Melbourne. 0000039284 00000 n
An option is to take your pumps off-grid and run them independently off a separate off-grid solar system. Is there anything that can be done about it? My assumption is (and I may be wrong after all) that the idea of using my own energy first before buying from the grid is an illusion, and in fact it only appears like that because all the energy from the inverter (up to 5kW) is measured as exported, all energy required by the house is actually imported from the grid (as if there was no solar system at all), and it is just because the exports are offset against the imports for billing, why it appears that my PV system is reducing the imports. The inverter reduces the amount of electrical energy supplied by the solar panels. So basically the whole local industry is going to be cactus until this is resolved. But this is at least partially because when you throttle back output, you also reduce the amount of voltage rise you are causing on your local connection to the point of interconnect which is probably contributing to the issue. Because you dont see the rather obvious shutdowns (or see them less), you might not notice your solar might be throttled back on a regular basis. Can one have micro-inverter panels without a gateway, and how would that be limited? If that doesnt worry you then you can get a battery and just hope it mostly pays for itself. xref
Do you know the situation here? Now, there are quite a few profiles on offer that can be programmed into the microinverters. Certainly this dumb meter is not capable of sending current from the inverter selectively to my home circuits and any excess to the grid? Voltage (V) measured at inverter terminals Also, if you are on the main grid the amount of power you are allowed to export can still be below the limits given or even zero, depending on how much additional solar capacity the local grid can handle at your location. I have spoken to one installer , but he couldnt really help me . Larger inverters that are export limited are allowed on a case by case basis. But, if you are living in an area where it is required to install a large solar system a situation around half of Australians are in then export limiting can allow a larger system with normally very minor losses of clean solar generation. Please stay on topic. The word first can be confusing. Unfortunately, SAPN wont allow more than 5 kilowatts of inverter capacity on an SWER line. March 2022 6 Powercor means Powercor Australia Limited, ABN 89 064 651 109. portal means the eConnect portal for CitiPower and . But if you dont use much electricity it may need to be very small, as I explain here: https://www.solarquotes.com.au/blog/zero-kw-export-solar/. P/Prated (%) Are Tesla Powerwall smart enough to let majority of power export to grid and only start charging battery as inverter approaches its export limit? My AS4777.2:2015 profile allows voltages up to 265v (for short periods, and shuts down on 10 minute averages above 258v). I have previously posted (or, submitted for posting), the proposition that what is needed, is a hybrid (not meaning in this instance, a hybrid inverter as is commonly used) inverter that is like a cross/combination, of the Goodwe GW5000-MS inverter (or, kind of, the GW10K-MS, in terms of power conversion), and the Goodwe GW5048D-ES; three GW5000-MS provides for up to 10kW of panels generating capacity, across three MPPTs (strings? Still, few people will want more than the 13.33 kilowatts of panel capacity single phase homes can generally install: The Bad: Homes with single-phase power on the main grid can have up to 5 kilowatts of inverter capacity but can usually get around this limit by installing an export limited solar inverter of up to 10 kilowatts. You could approach SAPN and ask for special permission to install more solar capacity on an SWER but I would not be optimistic about that. Exporting surplus solar power is good because it reduces fossil fuel generation and pays you a feed-in tariff that reduces electricity bills. 0000001916 00000 n
Despite the low feed-in tariff you will receive it can still be worthwhile, especially if you can shift some electricity consumption to the middle of the day. Though endless quibbling over unnecessary details might keep the presses churning, a FACT remains that Ive been using ever-more-cost-effective batteries since 1980. This is because even if there is only a refrigerator running during the day it will reduce the losses from export limiting and if an effort is made to shift electricity consumption to the middle of the day then losses can be mostly or entirely eliminated. Or is there a build up of voltage in the system? So, if a contractor or tradesman, using one of these during the day, or, another type of worker, gets home after work, and, plugs one of these in to charge, an immediate drain of 7 kW (I believe that it is actually 7.4 kW), and immediate significant drain is imposed on the grid, for several hours, during peak demand. But depending on our network capacity, export constraints may influence the size of the unit they install. 0000038296 00000 n
They hid the problem pretty well, because they do tend to reduce the amount of shutdowns. See image at http://www.johnrogers.com.au/battery_charging_noon.jpg. It is critical that you install an approved smart inverter and set it correctly. No matter how badly you may want to export limit your solar system, it can only be done in locations where its permitted. I have 13.25 kW of panels with a 9.8 kW LG Chem battery and a 10 kW inverter export limited to 5 kW. Once voltage thresholds etc are configure in the profile by the Envoy at install, each micro operates largely independently. 100% Solar Export Limiting Explained -- What It Is & Why It's Useful To give you example, you will probably find the profile you mention is probably throttling from a very low 250v and will ramp down to 20% at 265v. Instead the home can benefit from a small system, as I explain here: Ah yes I see. Energex doesnt automatically allow inverters over 5 kilowatts to be installed with export limiting, but currently regularly grants permission for single-phase homes on the main grid to install up to 10 kilowatts of inverter capacity with export limiting. Weve got a system that can be left alone in my opinion, so adding say 6.6kw and a 10kw battery makes good sense but what a task. Voltage (V) measured at inverter terminals It is delivering 8 kilowatts of solar power. We just had a 30kW inverter solar install for our business and it has been limited to 1.8kW export. After (almost) three months with no reply, has any reason been given, as to why export limited inverters are not allowed for single phase grid connections to the SWIS grid in WA? One thing I find is that Voltage control works well: instead of the inverter resetting if the voltage gets too high, my inverters roll back output, so it actually helps my neighbors too because their inverters reset less often. Were seeing a real lift in the number of customers able to export excess solar back into the grid in these areas, which were among the most constrained in our network only a few months ago, said Powercor General Manager Electricity Networks, Mark Clarke. Zero-sum game: The rise of solar export limits, and what can be done When an inverter is export limited, it has to know how much solar energy is being sent into the grid so it can immediately reduce output if its about to go over the limit. The installation of solar photovoltaic systems as well as the correct inverter settings are critical to ensuring customers get the most for their investment in this technology. Have a good christmas. I think the installers like the Volt-watt modes, because if you dont know where to look they hid the problem at your expense anyway. As per current standards, a single phase premises is limited to 10kW generation and 5kW export. Your meter is on the connection between the mains network on one side and the combination of your inverter and your loads on the other side. 0000005359 00000 n
I just dont understand it. Normally it makes more sense to buy a second, separate system, than to expand an existing one. These consumption spikes go past the Solar energy being limited suggesting were drawing from the grid! hour of charging is enough to drive 35km.. I have not been able to get an answer from Growatt Australia yet, it seems there is a bit of a cover-up going on. Information on whether export limiting is allowed can be found here, but I am going to present the information differently for both ease of use and to make my boss think Ive done something useful. 0000039096 00000 n
Solar customers who currently have a limit on the amount they can export are invited to contact Powercor to reapply for an export agreement based on the greater capacity now available on the network. It does this by adjusting the MPPT but instead of working to maximize power from the panels it reduces it. But if people send a lot of power into the line then the voltage at the far end, instead of being lower than at the sending end, becomes higher. 44% leading What made the situation all the more frustrating is periods of high congestion which can threaten the stability of a local network can be quite brief. I installed 6.6kw solar panels and have Goodwe 5kw inverter and applied for export limit of 5kw. Why my Power Limit is set to ON with the % whereas her Power Limit is set to OFF and she has been exporting. Thank you. Great article and content on this website I have divided Australias regions into three categories: The information below assumes the property is on the main grid. The majority of customers are approved for the export level they request. Solar system size limits explained by state | Solar Choice I think is is utter madness that the VIC government is handing out generous rebates of $1850.00 and 4 year interest free loans of up to $1850.00 and Powercor has zero feed in capacity for excess solar power. This means you tend to see panels at the end of strings shutdown soonest on voltage risk conditions, as they have the highest voltage rise being at the end of the string. In an Enphase system, that is with the Envoy-S with consumption monitoring. amended or replaced from time to time. I realise that all the political parties in the the WA state parliament and especially, the Synergy/Western Power conglomerate, that controls approvals of domestic rooftop photovoltaic systems connected to the SWIS grid, are opposed to domestic rooftop photovoltaic systems (even though we stabilise and sustain the grid), but, I am wondering whether any reason has ever been given by the oppressive authorities, for banning export limited inverters in WA. 1. I think I was partially wrong about how my PV is connected to the home and the meter. In exchange, the customer receives a small rebate on their bill for every kilowatt-hour (kWh) they export. In most cases, if you had your envoy shut off, the micros would start and work on their own and independently of the envoy, and in fact of each other. We respect your privacy and you can opt out from the newsletter at any time. As such, unless the investment pays for itself within at most 5-6 years, IMHO it is not a good investment/waste of money and natural resources. It would definitely be better if we didnt need to limit the amount of power solar systems sent into the grid. If you are interested you can read about this here: https://www.solarquotes.com.au/inverters/mppt/. (Image from Finns Tesla App). Hi i want to install solar with no power If a home cant export any power at all then there is no financial reason to install a large solar system. AS4777.2:2015 has some rather low default recommendations, which can be tweaked up as no doubt my profile has allowed. Even if I were exporting 100% of it, it still would only bring down my bills by a tiny amount per month. Actually I made a chart showing the percentage of electricity lines in each state that were SWER but I left it out for the sake of brevity. There may well be a tipping point in battery prices where a drought of mid day solar will be followed by very little evening use and possibly large numbers of households abandoning the grid altogether. The solar installer or customer must have sought and received pre-approval from us for the requested capacity of the generator. Youll also start receiving the SolarQuotes weekly newsletter, keeping you up to date on all the latest developments on Australias solar scene. How do I get around this with SAPN , am I allowed to export limit on a swer line in Sth Aust. On a related note, we mentioned yesterday that over the border in South Australia, SA Power Networks is readying to ramp up flexible solar exports in an effort to support more solar installations and its pretty clever stuff. By the time he was eight, he was already focused on using the power of the sun to stop fossil fuel emissions destabilizing the climate. NSWs Essential Energy area: Regional NSW. (Note: it is possible to install a larger system, say 10kW on a single phase property and meet the Powercor rules by export limiting the system .